Celestica Documentation Portal

Find your product documents here

PSU Specifications

Technical specifications, wattage configurations, and line-level redundancy behavior for DS1000 and power supply modules.

DS1000 and support redundant, hot-swappable AC power supply modules. The power supply supports input voltage from 100~240VAC at 50~60Hz VAC. Multiple power supply wattage options are offered to match the desired Power Over Ethernet requirement of the end user.

Important:

This product supports the use of Titanium-rated PSUs and Platinum-rated PSUs, but does not support mixed use.

Only use PSUs with identical part numbers. Two Titanium-rated PSUs with different part numbers is not supported.

Case 1: For a whole system initial power up, if the system is powered up with non-matching PSUs, the system will not function (allow data I/O) until a valid configuration is installed.

Case 2: If a PSU is replaced with a non-matching PSU while the system is functioning, the system will power off the newly inserted PSU and trigger an alarm mix log and the enclosure fault LED.

Case 3: All PSUs are of the same certified rating (Titanium or Platinum) but the part numbers do not match.

Note: The PSU AC input range is 100v to 264v RMS.
CAUTION: Only use PSUs with identical part numbers. Failure to do so will cause a system error.

1600W Power Module

Two 1600W PSUs are used on the ES2010-48CP model, supporting Front-to-Back (F2B) and Back-to-Front (B2F) airflow directions:

  • F2B (Front-to-Back) P/N: G1482-1600WNA
  • B2F (Back-to-Front) P/N: G1482-1600WRA
Important: Only when this PSU is used in high-line mode (200-240V), the output power of the PSU can reach 1600W. When operating in low-line mode (100-127V), the output power is reduced to 1000W.
CAUTION: During normal operation the PSUs do support 1+1 redundancy. If the total system power demand exceeds the power capacity of a single PSU, the PSUs cannot support 1+1 redundancy .

920W Power Module

Two 920W PSUs are used on the ES2010-24CP model, supporting F2B and B2F airflow directions:

  • F2B (Front-to-Back) P/N: G1482-0920WNA
  • B2F (Back-to-Front) P/N: G1482-0920WRA
CAUTION: During normal operation the PSUs do support 1+1 redundancy. If the total system power demand exceeds the power capacity of a single PSU, the PSUs cannot support 1+1 redundancy .

550W Power Module

Two 550W PSUs are used on the DS2010 and ES2010-24C models.

  • F2B P/N: G1251-0550WNA
  • B2F P/N: G1251-0550WRA
  • F2B P/N: R3194-PSA52-02 / DPS-550AB-55 (F2B airflow only)

In case of a fan fault on 550W PSUs, the modules shut off output power and require an AC power cycle to restore operation after the fault is cleared.

CAUTION: Airflow direction Front to Back (F2B) or Back to Front (B2F) must match for all power supplies.