Chassis Installation

DS5000 is designed to be installed in a standard 19'' four post rack. The bracket kit is only for 19 inch (483mm) wide, with a depth ranging from 22 inches ~ 33.5 inches (558mm ~ 850mm) as measured from rack post to rack post. This chapter covers the tools and procedures necessary to correctly and safely install the DS5000 data center switch. Before beginning, create a clean, stable, and level work surface.

Note: The power distribution unit (PDU) location in the rack should avoid interference with the cable management accessory (CMA) and potential removal of field replaceable units (FRUs) from the rear of the chassis. A wider rack enclosure width is recommended along with suitable PDU and power cord plug orientation.
CAUTION: Use two or more people to mount chassis into rack.