BBU Power LED

BBU Power LED Valid States: OFF, BLINK, SOLID

  • OFF – Indicates that the auxiliary power device is NOT in use
  • SOLID – The Battery Module has DC input power or is providing power to the system during a backup/destage event

BBU Status LED Valid States: OFF, BLINK, SOLID

  • OFF – Output is off or out of tolerance, unable to supply power to volatile cache memory and/or de-staging function.
  • BLINK – Indicates the auxiliary power device is charging
  • SOLID – Indicates the auxiliary power device is fully charged
Table 1. BBU LED States
LED TypeDescriptionValid States
BBU Power LEDIndicates that the auxiliary power device is NOT in useOFF
BBU Power LEDThe Battery Module is providing power to hold up components in the system during standby power (Note: For this state is not implemented)BLINK
BBU Power LEDThe Battery Module has DC input power or is providing power to the system during a backup/destage eventSOLID
BBU Status LEDOutput is off or out of tolerance, unable to supply power to volatile cache memory and/or de-staging function.OFF
BBU Status LEDIndicates the auxiliary power device is chargingBLINK
BBU Status LEDIndicates the auxiliary power device is fully chargedSOLID

BBU Fault LED

BBU Fault LED Valid States: OFF, BLINK, SOLID

  • OFF – There have been NO isolated faults or conditions detected by the battery module with the auxiliary power device that can be serviced using service indicators.
  • BLINK – The APD has been identified.
  • SOLID – There has been a fault condition detected with the auxiliary power device that can be serviced using service indicators. The auxiliary power device is in a condition that permits repair or replacement activity if removable.