Controller

The SC6100 uses two (2) controllers, each having its own discrete server. The server consists of multiple FRUs (Field Replaceable Units), including a CPU, DIMMs, and various other components.

Note: This system should only be serviced by a trained technician.
Note: Do not attempt to use controller without cover in place. The cover must be used to ensure proper airflow and cooling.

CAUTION: Each controller is equipped with a battery backup unit (BBU). When a controller is unseated, a data save cycle is initiated. This cycle can last from three to five minutes. For safety, partially unseat the controller and wait until the data save cycle has concluded, indicated by the cessation of all LED activity, before fully removing the controller from chassis.
Warning: Do not remove the controller cover until all rear panel LEDs are off. Failure to do so may result in system damage, or shock.