General Safety Guidelines

  • Ensure line voltage and frequency match the equipment rating label.
  • Connect power cords only to grounded neutral electrical power outlets.
  • To completely remove power from dual-PSU switches, disconnect all power supply cords.
  • Never insert objects into chassis openings to avoid high-voltage electrical shock.
  • Avoid touching rotating fan blades during maintenance or replacement.
  • Wear an ESD wrist strap and antistatic uniform when handling circuit components.

Regulatory Statements

FCC Compliance (US): Complies with Part 15 Class A limits for commercial operation with unshielded RJ45 cables.

ICES-003 (Canada): Class A digital apparatus compliant.

CE Directive (Europe): Conforms to 2014/30/EU (EMC), 2014/35/EU (LVD), and 2011/65/EU (RoHS).

WEEE Directive: Equipment must be disposed of at designated electrical equipment recycling facilities.

VCCI (Japan): Class A equipment for commercial environments.

CCC (China): Certified for safe operation at altitudes ≤2000m and non-tropical climates. China RoHS Environmental Protection Use Period (EPUP) is 20 years.