Celestica Documentation Portal

Find your product documents here

LEDs

The indicator light on front panel of ES1050/EG1050/ES1010 series has 1 power supply indicator light, 1 fan status indicator light,1 alarm indicator light, and system automatic diagnoses LED,2 Ethernet management port indicator light,1 SFP indicator light, 96 Ethernet data port indicator light,4 SFP28 indicator light. They are shown below and described in the following table.

Table 1. System LED Indicator Description
Indicator LightFront Panel SignStateMeaning

Power status LED

PWR

Green light always on

2 PSU power supply normal

Amber light always on

Any one of the PSU status is incorrect.

Off

The system is AC power off.

Fan status LED

FAN

Green light always on

3 fans modules is normal

Amber light always on

Any one of the FANs is absent, or any of the FAN status is abnormal. FAN Status LED Amber On.

Off

The system is AC power off.

Alarm status LED

ALM

Green light always on

The system is normal

Amber light always on

Critical Alarm in system.

Green and Amber light Alternate 4Hz Blinking

Major Alarm in system.

Green and Amber light Alternate 1Hz Blinking

Minor Alarm in system.

Off

The system is AC power off.

System status LED

STAT

Green and Amber light Alternate Blinking

The system is normal

Off

The system is AC power off.

Table 2. Management Port Indicator Light Description
Indicator LightPanel SignState

ETHERNET port Activity light (right)

Green light Blink

The port is transmitting data.

Off

There is no data transmitting on port.

ETHERNET port Link light (left)

Amber light always on

The port is configured at 10M/100M speed

Green light always on

The port is configured at 1000M speed

Off

No connection or fail to connect.

Indicator light of SFP Port

Green light always on

The port link at 1000M speed

Green light Blink

The port link at 1000M speed and activity

Off

No connection or fail to connect.

Table 3. Data Port Indicator Light Description
Indicator lightPanel SignState

ETHERNET port Activity light (right)

Green light Blink

The port is transmitting data. Port PoE power Disabled.

Amber light Blink

The port is transmitting data. Port PoE power Enabled.

Amber light On

There is no data transmitting on port. Port PoE power Enabled.

Alternate Blink Amber/Green for 1 minute

Port PoE power Denied. Port PoE power Disabled.

Off

There is no data transmitting on port.

ETHERNET port Link light (left)

Green light always on

For ES1010-48C and ES1010-48CP: The port link is active at 1GbE mode.

For ES1050-48C,ES1050-48CP and EG1050-48CP: The port link is active at 2.5GbE mode.

Amber light always on

For ES1010-48C and ES1010-48CP: The port link is active at 10/100M mode.

For ES1050-48C,ES1050-48CP and EG1050-48CP: The port link is active at 10/1000M mode.

Off

No connection or fail to connect.

SFP28 port

Green light always on

The port link at 25GbE mode. There is no data transmitting on port.

Green light Blink

The port link at 25GbE mode. The port is transmitting data.

Amber light always on

The port link at 1/10GbE mode. There is no data transmitting on port.

Amber light Blink

The port link at 1/10GbE mode. The port is transmitting data.

Off

No connection or fail to connect.

Note: Before the SDK is loaded, the data port light is controlled by CPLD and is OFF by default. After the SDK is loaded, the light behavior of the data port is controlled by the SDK.
Table 4. PSU Indicator LED Description
Indicator LEDRear Panel SignStateMeaning

550W

P-1/P-2

Green light always on

PSU modules is normal

Red light always on

PSU detected an Error

Off

PSU module is power off

920W & 1600W

P-1/P-2

Left light always Green on

Right light always Green on

Power supply DC outputs on and OK

Left light is Green/0.5Hz flashing

Right light always Green on

AC present /Only standby outputs on

Left light always Red on

Right light always Green on

Power supply failure, PSU shut down

Left light always Green on

Right light is Red/0.5Hz flashing

One PSU is working normally, but the AC power supply of the other PSU is abnormal.