Product Overview
The DS3000 is an advanced distribution layer Ethernet switch for data center leaf and spine applications. Ideal use cases include campus, enterprise, and IP metropolitan networks.
Product Specifications
Type | DS3000 |
---|---|
Depth | 520 mm |
Height | 44 mm |
Width | 438 mm |
Weight | 10 Kg |
Power Input (VAC) | 90~264VAC(50~60Hz) |
Power Consumption (W) | 500W |
Operating Temperature (airflow front to back) | 0º - 45ºC |
Operating Temperature (airflow back to front) | 0º - 45ºC |
Operating Relative Humidity | 5% - 90 % |
Storage Temperature | -40º - 70ºC |
Storage Relative Humidity | 5% - 95% |
Front Panel
The front panel of the DS3000 is shown below:
The console port supports asynchronous mode. Set the data bit as 8, the stop bit as 1, the parity bit as none, the default baud rate as 115200bps.
Rear Panel
The rear panel of the DS3000 is shown below:
The back panel of DS3000 includes dual500W power supplies (providing redundancy), and four fans.
Port Description
DS3000 provides 32 QSFP28 ports, 1 SFP+ port and one RJ45 Ethernet port. The description is in the following:
Port mode |
Spec |
RJ45 port |
|
QSFP28 |
|
SFP+ |
|
Status LEDs
The indicator LEDs on front panel of the DS3000 are 32 QSFP28 and 1 SFP+ port indicator LEDs, two power supply indicator LEDs and a system automatic diagnostic LED. They are described in the following table.
Indicator LED | Front Panel Identifier | LED Status | Description |
---|---|---|---|
PSU | P1/P2 | Green On (solid) | PSUs operating normally |
Amber On (solid) | PSU fault exists | ||
Off | PSU not present / no power | ||
Alarm | ALM | Green On (solid) | No alarm |
Amber On (solid) | Critical alarm | ||
Amber On (blinking) | Major alarm: 4Hz blinking / Minor alarm: 1Hz blinking | ||
System | STAT | Green / Amber alternating (4Hz) | Default CPLD setting |
Green / Amber alternating (1Hz) | For systems running ONIE |
Indicator LED | Rear panel sign | Status | Description |
---|---|---|---|
Fan module indicator LED |
Fan1/FAN2/FAN3 /FAN4 |
Green On steadily | Fan is present and its status is normal. |
Amber On steadily |
Fan is present but its status is Alarm. | ||
Off |
Fan Tray is not present. | ||
ETHERNET port Activity LED (left) |
NA |
Green LED blink |
The port is transmitting data. |
Off |
There is no data transmitting on port. | ||
ETHERNET port Link LED (right) |
NA |
On with amber LED |
The port is configured at 10M/100M speed |
On with green LED |
The port is configured at 1000M speed | ||
off |
No connection or fail to connect. |
Indicator LED | Status | Description |
---|---|---|
Indicator LED of QSFP28 port |
First Green Blinking |
The port and the link are active in 100 GbE mode, and there is link activity. |
First Green On steadily |
The port and the link are active in 100 GbE mode, but there is no link activity. | |
All Amber Blinking |
The port and the link are active in 4x10 GbE mode, and there is link activity. | |
All Amber On steadily |
The port and the link are active in 4x10 GbE mode, but there is no link activity. | |
All Green Blinking |
The port and the link are active in 4x25 GbE mode, and there is link activity. | |
All Green On steadily |
The port and the link are active in 4x25 GbE mode, but there is no link activity. | |
Off |
The port is not active | |
Indicator LED of SFP+ port |
Green Blinking |
The port and the link are active in 10 GbE mode, and there is link activity. |
Amber Blinking |
The port and the link are active in 1 GbE mode, and there is link activity. | |
Green On steadily |
The port and the link are active in 10 GbE mode, but there is no link activity. | |
Amber On steadily |
The port and the link are active in 1 GbE mode, but there is no link activity. |
90~264VAC(50~60Hz) 3.4A~7.1A
R