Power Supply Unit (PSU)
Overview
The DS3000 storage enclosure is powered by two 500W redundant power supply units (PSUs) with the following features.
- 12V +/- 5%
- 12 V and 5 V hot-swappable controllers
- Temperature sensor and VPD
Power Supply Condition |
LED State |
Output on, normal operation |
Green |
No AC power to all power supplies |
Off |
AC present / Only VSB on (PSU off) |
1 Hz Blink Green |
AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power |
Amber |
Power supply warning events where the power supply continues to operate; high temp, high power, high current, slow fan, under voltage |
1 Hz Blink Amber |
Power supply critical event causing a shutdown; failure, over current protection (OCP), over voltage protection (OVP), fan failure |
Amber |
AC Power Cord
The AC power sockets are located on the rear of the chassis. Contact Celestica if you want to use other types of power cords.
This product supports the use of Titanium-rated PSUs and Platinum-rated PSUs, but does not support mixed use.
Only use PSUs with identical part numbers. Two Titanium-rated PSUs with different part numbers is not supported.
Case 1: For a whole system initial power up, if the system is powered up with non-matching PSUs, the system will not function (allow data I/O) until a valid configuration is installed.
Case 2: If a PSU is replaced with a non-matching PSU while the system is functioning, the system will power off the newly inserted PSU and trigger an alarm mix log and the enclosure fault LED.