DS2000 Product Overview

This document describes the general hardware design of the DS2000 switch.

DS2000 is a 48-port 10/25GbE and 8 port 100GbE switch in a compact 1U form factor that provides 2.0Tbps bandwidth, ideally suited for data center top of rack deployments and enterprise service aggregation.

Optimized for:

  • 10/25GbE Data Center Top of Rack

  • Enterprise Edge/Aggregation

  • Open and Third-Party Network Operating Systems

Product Specifications

TypeDS2000
Depth 520 mm
Height 44 mm
Width438 mm
Weight9.1 Kg
Power Input (VAC)~100 - 127 VAC & ~200 - 240 VAC (47-63Hz)
Power Consumption (W)<350W
Operating Temperature (airflow front to back)0º - 45º C @900m
Operating Temperature (airflow back to front)0º - 45º C @900m
Operating Relative Humidity5% - 95%

Product Orientation

Figure 1. DS2000 Front Panel View
Figure 2. DS2000 Rear Panel View
Note: The user can perform local and telnet configuration through this port. The console port supports asynchronous mode, 8 data bits, 1 stop bit, no parity bit. The default baud rate is 115200 bps.
Note: The USB port supports data transmission only. It does not supply power.

Status LEDs

The front panel of the DS2000 has 48 SFP28 and 8 QSFP28 port indicator LEDs. These LEDs are described in the following tables.

Table 1. Port Indicator LEDs of QSFP28
LED StateMeaning
1st LED: Green/Amber
Green onPort link operating at max port speed
Green blinkingPort activity operating at max port speed
Amber onPort link operating at lower speed
Amber blinkingPort activity operating at lower speed
OffPort link down
All four LEDs are used when 4x25G or 4x10G mode is running on QSFP28 port
Green on4x25G link on QSFP28 port
Green blinking4x25G activity on QSFP28 port
Amber on4x10G link on QSFP28 port
Amber on4x10G activity on QSFP28 port
OffPort link down
Table 2. Port Indicator LEDs of SFP28
LED StateMeaning
One Port Link/ Activity status Green/Amber bi-colored LED is provided for each front panel port
Green onPort link operating at max port speed
Green blinkingPort activity operating at max port speed
Amber onPort link operating at lower speed
Amber blinkingPort activity operating at lower speed
OffPort link down

After powering on, all the port LEDs will self-check (all colors blink in sequence), and then turn green.

After Software Development Kit (SDK)/Network Operating System (NOS) runs, each port's LEDs will function as listed in the following table:

Figure 3. Indicator LEDs of 48 SFP28 and 8 QSFP28 ports
Table 3. Front Panel Status LEDs
Indicator LEDFront Panel SignLED StateMeaning
PowerPWRGreen OnAll PSUs operating normally
Amber OnOne or more PSUs absent or operating abnormally
FanFANGreen OnAll fans operating normally
Amber OnOne or more fans absent or operating abnormally
OffNo power to system
AlarmALMGreen OnNo alarm
Amber OnCritical alarm
Amber 1Hz blinkingMinor alarm
Amber 4Hz blinkingMajor alarm
SystemSTATGreen / Amber - Alternate blinkingNormal operation
OffNo power to system
Table 4. Rear Panel Status LEDs
Indicator LEDRear Panel SignLED StateMeaning
Fan moduleFAN1 / FAN2 / FAN3 / FAN4GreenAll fans operating normally
AmberFan(s) operating abnormally
OffFan absent
PSU moduleP-1 / P-2GreenAll PSUs operating normally
RedPSU error(s) detected
OffPSU is off
Table 5. Management Port Indicator LEDs
Indicator LEDStatusDescription
ETHERNET Port (left) Green blinking Port transmits data
Off Port does not transmit data
ETHERNET Port (right) Amber On Port is configured at 10M/100M speed
Green On Port is configured at 1000M speed
Off No connection or failed to connect

Port Description

DS2000 provides 48 SFP28 ports, eight QSFP28 ports, one RJ45 Ethernet port, one Serial Console port and one USB port. Port types are described as follows:

Table 6. DS2000 Port Descriptions

Port mode

Spec

RJ45 port

  • 10/100/1000Mbps auto negotiation
  • MDI/MDI-X cable mode auto negotiation

Serial Console port

  • Supports a minimum 9600 and 115200 baud rates, eight data bits, one stop bit and no parity

USB port

  • USB2.0 host type A interface

QSFP28

  • Supports parallel multimode fiber OM3 and OM4 for short reach applications 100Gbase-SR4.

  • Supports long reach optics 100Gbase-LR4 (10 km) over single mode fiber.

  • Supports copper 100Gbase-CR4 connections.

    • 1M 30AWG

    • 3M 28AWG

    • 5M 26AWG

  • Does not require switch device reboot for 100G port mode change to 4x25G .

  • Uses break out cable for 100G port mode change to 4x25G mode.

SFP28

  • Supports parallel multimode fiber OM3 and OM4 for short reach applications 10Gbase-SR4.

  • Supports long reach optics 10Gbase-LR4 (10 km) over single mode fiber.

  • Supports copper 10Gbase-CR4 connections.

    • 1M 30AWG

    • 3M 28AWG

    • 5M 26AWG

Power Supply Unit (PSU)

The DS2000 switch contains two 550W PSUs with the support of two airflow options: front-to-back (F2B) and back-to-front (B2F).

Each PSU's maximum output power is 550W with an input voltage of 90VAC~264VAC and an output voltage of 12 VDC +/- 5%. The PSU includes a fan and a handle at the back of the power supply to support hot plug pull-out and insertion.
Figure 4. PSU
CAUTION: Different airflow power modules can not be mix used.

Fan Module

DS2000 switch contains four fan modules in the standard configuration. The rotation speed of the fan adjusts and adapts to the system temperature. It provides two airflow options: front-to-back (F2B) and back-to-front (B2F).

Figure 5. Fan Module
CAUTION: Different airflow power modules can not be mix used.