Troubleshooting ESM - LEDs Solid On
Note: The ESM can be replaced without powering off. Leave the enclosure powered on.
- Use CLI CMD
poa
to check if the ESM is in Lock Down mode. - If the ESM is in Lock Down mode, try the following:
- Reset the ESM.
-
Upgrade ESM firmware to same version as peer's ESM.
-
If resetting and upgrading do not work, remove the ESM and verify that the pins on the backplane and ESM are not bent. See: ESM Canister Removal. Replace ESM with another one if any physical damage is found, which should have the same FW version with the peer ESM. For installation, see: ESM Canister Installation
- If no lock down mode is found, use CLI CMDs
temp get
,fan get
, andpower get
to check for component faults. - If any faults are found, replace related faulted devices and keep watching the system for a period of time to check whether this fault can be recovered.
- If the fault still exists, remove the ESM and verify that the pins on the backplane and ESM are not bent. See: ESM Canister Removal to remove the canister. For canister installation, see: ESM Canister Installation